System shutdown and precautions


2023/09/08

When the membrane system is shut down, it is necessary to flush the entire membrane system with pre treated qualified water supply or produced water, in order to replace the high salinity concentrated water from the pressure vessel and membrane components, until the conductivity of the concentrated water outlet is close to the conductivity of the inlet water, and proceed at a low pressure of about 3.0 bar (43.5 psi). High flow rate is beneficial for improving the flushing effect, but the pressure difference between the components or pressure vessels at both ends should not exceed the maximum specified value. The low-pressure flushing inlet should not contain chemicals used for pre-treatment, nor should it contain scale inhibitors. After the flushing is completed, completely close the inlet valve. The reverse osmosis nanofiltration system should be completely filled with water. It is recommended to set the concentrated water discharge pipeline to an inverted U-shaped shape, with the top of the inverted U-shaped pipeline higher than the highest straight pressure vessel and a siphon breaking device installed.

Factors affecting the performance of reverse osmosis and nanofiltration membranes


2023/09/08

1. Recovery rate The percentage of water supply in a membrane system that is converted into permeate or permeate. The design of the membrane system is based on the preset inlet water quality, and the concentrated water valve set on the concentrated water pipeline can adjust and set a reasonable recovery rate. Enhanced pre-treatment configurations can greatly improve recovery rates. 2. Desalination rate The percentage of total soluble substance concentration removed from the system inlet through reverse osmosis membrane, or the percentage of specific components such as divalent ions or organic matter removed through nanofiltration membrane.

< 1...5678 > proceed page

Empfohlene Neuigkeiten

Where Does RO Concentrate Go?

2026/09/16

RO concentrate is not the end point of water treatment.

How to Prevent Reverse Osmosis Membrane Fouling? A Comprehensive Analysis of Four Major Prevention and Control Strategies

2026/09/11

Only when every barrier is properly implemented can reverse osmosis membranes shift from "frequent clogging" to "long-cycle stable operation".

Why Do Reverse Osmosis Membranes "Clog"? A Complete Guide to Four Major Types of Membrane Fouling

2026/09/07

Membrane fouling is not a question of "if" but "when, what type, and how to respond." Fouling is inevitable, but it is predictable, controllable, and recoverable.

From Shenzhen to Mexico City: Daltonen Membrane Technology Debuts at Aquatech Mexico 2026

2026/09/04

Aquatech Mexico 2026 has concluded successfully, but Daltonen Membrane Technology will never slow down its pace of going global.

Membrane Replacement Is More Than Just Swapping Membranes: Have You Considered the Compatibility of Supporting Consumables?

2026/08/17

Without properly matched supporting components, even the highest-quality membranes may underperform.